Professional emergency lighting design, installation, upgrades and planned maintenance for commercial premises across London and the South East
Comprehensive emergency lighting services from initial design through to ongoing maintenance
Risk-led emergency lighting design tailored to your building layout, escape routes and fire risk assessment. Professional installation aligned to BS 5266 standards with comprehensive commissioning.
Planned maintenance by competent engineers with documented test results, defect reporting and recommendations aligned to BS 5266 and manufacturer guidance.
Replacement of older fluorescent emergency fittings with modern LED equivalents, improving reliability and reducing maintenance burden while bringing systems into current compliance.
Diagnosis and rectification of failed fittings, batteries and circuits. Coordinated emergency lighting maintenance across multiple sites with centralized documentation.
We work across a wide range of commercial and public sector premises throughout London and the South East.
Escape route coverage
Public area protection
High-bay environments
Schools and universities
Hospitals and care homes
Hotels and venues
Housing associations
Local authority buildings
Understanding your legal obligations for emergency lighting systems
The Responsible Person must ensure fire safety measures including emergency lighting are maintained in effective working order with appropriate records kept.
Identifies where emergency lighting is needed
Regular testing and maintenance required
Documented test results and maintenance records
The British Standard code of practice for emergency lighting design, installation and maintenance in buildings.
Coverage of escape routes and open areas
Minimum 3-hour emergency duration typically required
Monthly functional tests and annual duration tests
BS 5266 mandates regular testing and maintenance to ensure system reliability
Test each emergency fitting for correct operation by simulating mains failure. Verify illumination and charging indicators.
Comprehensive inspection and testing by a competent engineer including battery condition checks and system verification.
Complete duration test to verify each fitting can maintain illumination for the required period (typically 3 hours).
Problems we regularly diagnose and resolve
Replacement of exhausted batteries and faulty charging circuits to restore emergency duration and system integrity.
Solution: Battery replacement and charger verificationRepair or replacement of failed emergency light fittings and exit signs to maintain adequate escape route coverage.
Solution: Fitting repair or replacementRelocation or addition of fittings following layout changes to maintain adequate coverage of escape routes.
Solution: Coverage assessment and repositioningReconstruction of asset registers, test records and compliance documentation to support ongoing management.
Solution: Documentation rebuild and labellingOur structured approach ensures quality outcomes on every project
Site visit to assess current provision, identify deficiencies and understand operational requirements and constraints.
Clear written proposal covering scope of work, compliance approach, risk assessments and method statements where applicable.
Risk-led design aligned to BS 5266, fire risk assessment findings and building layout with device selection and positioning.
Professional installation of new systems or remedial work on existing installations by qualified engineers with minimal disruption.
Comprehensive functional testing and verification of coverage, duration and system integrity aligned to applicable standards.
Full handover pack including asset registers, test certificates, user guidance and ongoing planned maintenance support.
Professional emergency lighting design, installation and maintenance aligned to BS 5266 standards